<tr id="stl47"><source id="stl47"></source></tr>

<form id="stl47"><span id="stl47"><track id="stl47"></track></span></form>
<wbr id="stl47"></wbr>
    <form id="stl47"></form>
      <sub id="stl47"></sub>
        <tr id="stl47"></tr>
      1. <form id="stl47"></form>
        <form id="stl47"><th id="stl47"><noscript id="stl47"></noscript></th></form>

          <sub id="stl47"></sub><table id="stl47"><th id="stl47"><track id="stl47"></track></th></table>
          西門子SM335快速模擬I/O模塊
          西門子SM335快速模擬I/O模塊
          產品價格:¥12(人民幣)
        1. 規格:原裝進口
        2. 發貨地:上海
        3. 品牌:
        4. 最小起訂量:1臺
        5. 免費會員
          會員級別:試用會員
          認證類型:未認證
          企業證件:未通過
          認證信息:未認證

          商鋪名稱:上海啟水自動化科技有限公司

          聯系人:李明松(先生)

          聯系手機:

          固定電話:

          企業郵箱:shanghailms888@163.com

          聯系地址:上海市松江區樂都路251號樂都大廈16G

          郵編:201600

          聯系我時,請說是在焊材網上看到的,謝謝!

          商品詳情

             

            上海啟水自動化科技有限公司(西門子核心分銷商)

             聯系人 :李 松( 銷售經理 24小時服務熱線 186 0165 7819

             電話( Tel ): 021-60641328    

            工作( Q Q  1471187088 郵箱( Email )::1471187088@qq.com  

             地址( Add ):上海市松江區弘翔路58195

            用于 SIMATIC S7-300 的高速模擬量輸入和輸出

             用于連接模擬傳感器和激勵器

            SM 335

            Module-specific data

            Number of inputs

            4

            Number of outputs

            4

            Cable length, shielded

            200 m

            With wire-break monitoring in range 0 V to 10 V

            30 m

            Voltages, currents, potentials

            Rated load voltage

            24 V DC

            Polarity reversal protection

            yes

            Galvanic isolation

            yes

            Permissible potential difference

             

            • between inputs (UCM)

            3 V

            • between input (M terminal) and central grounding point

            75 V DC

            • Insulation

            tested at 500 V DC

            Current consumption

             

            • from S7-300 backplane bus, max.

            75 mA

            • from L+, max.

            150 mA

            Power losses, max.

            3.6 W

            Status, interrupts, diagnostics

            Interrupts

             

            • Limit value interrupt

            no

            • Cycle end interrupt

            yes, parameterizable

            • Diagnostics interrupt

            yes, parameterizable

            Diagnostic functions

             

            • Fault display for grouped fault

            yes, red LED

            • Diagnostic information can be read out

            yes

            Analog value generation for inputs

            Measuring principle

            successive approximation

            Conversion time per channel

            200 μs

            • Basic conversion time for 4 channels, max.

            1 ms

            Resolution

             

            • Bipolar

            13 bits + sign

            • Unipolar

            14 bits

            Analog inputs

            Interference between inputs

             

            • at 50 Hz

            65 dB

            • at 60 Hz

            65 dB

            Operational limits (over entire temperature range, referred to input range)

             

            • with voltage measurement

            ± 0.15 % (with 14-bit resolution)

            • with current measurement

            0.25 %

            Basic error limit (operational limits at 25 °C, referred to input range)

            0.13 % (with 14-bit resolution)

            Temperature error (referred to input range)

            ± 0.1 % (with 14-bit resolution)

            Linearity error (referred to input range)

            ± 0.015 %

            Repeatability (under steady-state conditions, at 25 °C, referred to input range)

            ± 0.05 %

            Encoder selection data

            Input range (rated values)/input resistance

             

            • Voltage

            ± 1 V; ± 10 V; ± 2.5 V; 0 V to 2 V; 0 V to 10 V: 10 MΩ

            • Current

            ± 10 mA; 0 mA to 20 mA; 4 mA to 20 mA: 100 Ω

            Permissible input voltage for voltage input (destruction limit)

            ± 30 V

            Permissible input current for current input (destruction limit)

            25 mA

            Connection of signal encoder

             

            • for voltage measurement

            possible

            • for current measurement

             

            - as 2-wire transducer

            not possible

            - as 4-wire transducer

            possible

            • for resistance measurement

            not possible

            Output for supplying the transducer (short-circuit proof)

            10 V/25 mA

            Data for encoder supply output

            Rated voltage

            10 V

            Output current, max.

            25 mA

            Short-circuit proof

            yes

            Operating limits (over entire temperature range)

            0.2 %

            Temperature error

            0.002 %/K

            Basic error for rated voltage

            0.1 %

            Outputs

            Resolution(including overcontrol range)

             

            • ± 10 V

            11 bits + sign

            • from 0 V to 10 V

            12 bits

            Conversion time per channel, max.

            800 μs

            Settling time

             

            • for resistive load

            < 0.1 ms

            • for capacitive load

            < 3.3 ms

            • for inductive load

            < 0.5 ms

            Interference between outputs

            40 dB

            Substitute values can be switched in

            yes

            Operational limits (over entire temperature range, referred to output range)

            0.5 %

            Basic error limit (operational limits at 25 °C, referred to output range)

            0.2 %

            Linearity error (referred to output range)

            ± 0.05 %

            Repeatability (under steady-state conditions, at 25 °C, referred to output range)

            ± 0.05 %

            Output ripple (referred to output range)

            ± 0.05 %

            Actuator selection data

            Input ranges (rated values)

            ± 10 V and 0 V to 10 V (switchover)

            Load impedance

             

            • for voltage outputs, min.

            3 kΩ

            • for capacitive load, max.

            1 μF

            • for inductive load, max.

            1 mH

            Voltage output

             

            • Short-circuit proof

            yes

            • Short-circuit current, max.

            8 mA

            Connection of the actuators for voltage output

             

            • as 2-wire connection

            possible

            • as 4-wire connection

            not possible

            Dimensions and weight

            Dimensions (w x h x d)

            40 mm x 125 mm x 120 mm

            Weight, approx.

            300 g




             