          HA44e/475-4  HA4/465-4
          HA44e/475-4 HA4/465-4
          產品價格:¥12000(人民幣)
        1. 規格:HA44e/475-4 HA4/465-4
        2. 發貨地:福州
        3. 品牌:
        4. 最小起訂量:1個
        5. 誠信商家
          會員級別:鉆石會員
          認證類型:企業認證
          企業證件:通過認證

          商鋪名稱:福州天行健節能科技有限公司

          聯系人:葉工(小姐)

          聯系手機:

          固定電話:

          企業郵箱:2961668110@qq.com

          聯系地址:福建省福州市鼓樓區水部街道六一中路71號皇島中環F夾層T22單元

          郵編:350000

          聯系我時,請說是在焊材網上看到的,謝謝!

          商品詳情

            HA44e/475-4  HA4/465-4

            福州天行健provide原廠GEA-Bock船用壓縮機及壓縮機零部件

            福州天行健節能科技有限公司提供歐美日船舶原裝進口品牌零部件



            HA single-stage compressors
            The HA-system - the best solution for deep-freezing!

            Special features:
            - Direct intake with external ventilation
            - Suction gas intake directly into the compressor
            - Motor cooled by an integrated ventilation unit

            This reduces the compressed gas temperature and thus expands the range of application while at the same time increasing capacity (deep-freeze, R22, R404A). At the same time, the compressor is physically separated from the compressor, with advantages particularly in the case of motor damage.

            Technical data

            HAX44e/475-4

            Application Refrigeration & AC

            Compressor refrigeration capacity 7.43 kW

            Power consumption 4.62 kW

            Current draw (400 V) 12.30 A

            Mass flow 0.056 kg/s

            at following operating condition:

            Refrigerant R404A, R507

            Reference temperature Dew point

            Evaporating temperature -35.0 °C

            Condensing temperature 40.0 °C

            Supply frequency 50 Hz

            Voltage 400 V

            Suction gas temperature 20 °C

            Subcooling (outside cond.) 0 K

            Number of cylinders / Bore / Stroke 4 / 55 mm / 50 mm

            Displacement 50/60 Hz (1450/1740 1/min) 41,30 / 49,60 m3/h

            Voltage 1) 380-420V Y/YY -3- 50Hz PW

            440-480V Y/YY -3- 60Hz PW

            Winding divided into 50% / 50%

            Max. working current 2) 15.2 A

            Max. power consumption 2) 7.6 kW

            Starting current (rotor blocked) 2) 87.0 / 149.0 A

            Motor protection INT69 G

            Protection terminal box / HA-fan IP 66 / IP 44

            Voltage HA-fan 230 V - 1 - 50/60 Hz, 140 W

            Protection terminal box IP 66

            Weight 174 kg

            Max. permissible overpressure (g) (LP/HP) 3) 19 / 28 bar

            Connection suction line SV 35 mm - 1 3/8 "

            Connection discharge line DV 28 mm - 1 1/8 "

            Lubrication Oil pump

            Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A BOCKlub E55

            Oil type R22 BOCKlub A46

            Oil charge 2,7 Ltr.

            Oil sump heater 230 V - 1 - 50/60 Hz, 160 W

            Dimensions Length / Width / Height 717 / 361 / 408 mm

            Sound power level LWA 4) 81 db(A) @ -35 °C / +40 °C

            Sound pressure level LpA 4) 68 dB(A) @ -35 °C / +40 °C

            Scope of supply

            Semi-hermetic four-cylinder reciprocating compressor with drive motor for part winding start

            380-420 V Y/YY - 3 - 50 Hz

            440-480 V Y/YY - 3 - 60 Hz

            Single-section compressor housing with hermetically integrated electric motor

            Oil pump

            Motor is cooled by an integrated ventilator with air deflection hood.

            230 V - 1 - 50/60 Hz, IP44, 140 W, 0,71 A

            Winding protection with PTC resistor sensors and electronic trigger unit INT69 G

            115-230 V AC, 50/60 Hz, IP00

            Rear bearing flange prepared for oil differential pressure sensor DELTA-P II

            Possibility of connection of oil level controllers ESK, AC+R or CARLY

            Possibility of connection of oil level controllers Traxoil 5)

            Possibility for connection of oil pressure safety switch MP54

            Oil charge:

            HA: BOCKlub A46

            HAX: BOCKlub E55

            Sight glass

            Pressure relief valve

            Suction and discharge line valve

            Inert gas charge

            4 anti-vibration pads enclosed

            Accessories

            Start unloader by means of a ESS (Electronic Soft Start), 400 V - 3 - 50/60 Hz, IP20 (Connection clamps IP00) for installation in switch cabinet 6)

            Digital capacity regulator DCR14 230 V - 1 - 50/60 Hz, IP65

            1 digital capacity regulator = 50% residual capacity 7)

            Cylinder cover prepared for digital capacity regulator

            Oil sump heater

            230 V - 1 - 50/60 Hz, 160 W, IP66

            PTC heater self-regulating

            Thermal protection thermostat per cylinder cover 7)

            Oil pressure safety switch MP54 230 V - 1 - 50/60 Hz, IP20 6)

            Oil differential pressure sensor DELTA-P II 220-240 V - 1 - 50/60 Hz 8)

            Connection piece suction and discharge valve in welding design 9)

            USB converter for INT69 G Diagnose 6)

            Oil temperature sensor (Pt1000, for external evaluation) 7)

            INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable)

            DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 6)

            Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 6)

            Intermediate flange for suction valve on right seen from oil pump in conjunction with capacity regulator 6)

            Step protection

            Special voltage and/or frequency (on request)

            Notes

            1) Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request

            All data are based on voltage rms values

            PW = part winding, motors for part winding starting

            (no start unloaders required)

            Designs for Y/D on request

            2) - The stated value for the max. power consumption is valid for the adjusted power supply.

            - Starting current (rotor blocked):

            Part winding (PW) motors: Winding 1 / Winding 1+2

            Delta/Star (Δ/Y) motors: Δ / Y

            - Take account of the max. operating current / max. power consumption for designing fuses, supply lines and safety devices. Fuse: Consumption category AC3.

            3) LP = Low pressure

            HP = High pressure

            4) Declared dual-number noise emission values are in accordance with ISO 4871. The corresponding uncertainty to the sound power level is KWA = 2,5 dB and to the sound pressure level is KpA = 2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the standard rating points according to EN 12900.

            A-weighted sound power level LWA (re 1 pW), in decibel. To determine the values, measurement methods of the ISO 3740 standard with accuracy class 2 or higher were used .

            A-weighted sound pressure level LpA (re 20 μPa), in decibel. The values are calculated from the sound power level in accordance with ISO 11203: LpA = LWA - Q2 at a distance of d = 1m to the reference box.

            5) Only with additional adapter possible

            6) Enclosure

            7) Mounted

            8) Enclosure (screw-in part mounted)

            9) On request